Slim Size 0-10V Dimmable Driver 60W(IP20)
SMT-012-060VDSP
0-10V Dimmable Driver
SMARTS
SMT-012-060VDSP is a Slim 24V dimmable 60W Constant voltage led strip driver power supply With perfect dimming function It can provide a stable power supply
model
SMT-012-060VDSP
SMT-024-060VDS...
SMT-012-060VDSP is a Slim 24V dimmable 60W Constant voltage led strip driver power supply With perfect dimming function It can provide a stable power supply
model | SMT-012-060VDSP | SMT-024-060VDSP | |
Output | DC Voltage | 12VDC | 24VDC |
Voltage Accuracy | ±5% | ±5% | |
Rated current | 5.0Amp | 2.5Amp | |
Rated power | 60W | 60W | |
Voltage Regulation | ±0.5% | ||
Load Regulation | ±1% | ||
Input | Voltage Range | 100-277 VAC | |
Frequency Range | 47~63HZ | ||
Power Factor ( Typ.) | PF≧0.99/110V ; PF≧0.98/277V | ||
Full Load Efficiency(Typ.) | 84%@120VAC 86%@277VAC | 83%@120VAC 85%@277VAC | |
AC Current(Typ.) | 0.9A | ||
THD(Typ. ) @ full load | <10%@120VAC <15%@277VAC | ||
Inrush Current(Typ.) | 6.85A, 50%, 640us & 16.8A, 50%, 640us@2770VAC | ||
Leakage current | <0.74mA/110VAC; ﹤0.25mA/277VAC | ||
Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. | |
Over Loading | ≤120% shut down o/p voltage, re-power on to recover | ||
Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||
Environment | Working TEMP. | -40~+60℃ | |
Working Humidity | 20~90%RH,non-condensing | ||
Storage TEM.,Humidity | -40~+80℃,10~95%RH | ||
TEMP.coefficient | ±0.03%/℃(0~50℃) | ||
Vibration | 10~500Hz, 2G 10min./1 cycle,period for 60min. each along X,Y,Z axes | ||
Safety&EMC | Safety standards | UL8750 +UL 1310, CAN/CSA-C22.2 No.250.13 | |
Withstand voltage | I/P-O/P:1.88KVac | ||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||
EMC EMISSION | FCC 47 CFR Part 15 ,Subpart B | ||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,,11, ,Alight industry level | ||
Others | Weight | 0.45Kg | |
Size | 300*32*20mm (L*W*H) | ||
packing | 50PCS/CTN Carton size: 330*330*130mm | ||
Notes | 1. All parameters NOT specially mentioned are measured at 110VAC, 277VAC input , Rated load and 25℃of ambient temperature. | ||
2. Tolerance:includes set us tolerance,line regulation and load regulation . | |||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |
?