Waterproof LED Driver 250W
SMT-012-250VW
Non-dimmable LED Driver
SMARTS
Non Dim Waterproof LED Driver 250W Suitable for outdoor lighting such as street lights.12Vdc LED power supply 250W with short-circuit and overload protection.Longer service life than ordinary power...
Non Dim Waterproof LED Driver 250W Suitable for outdoor lighting such as street lights.12Vdc LED power supply 250W with short-circuit and overload protection.Longer service life than ordinary power supplies
MODEL | SMT-012-250VW | SMT-024-250VW | |
OUTPUT | DC VOLTAGE | DC12V | DC24V |
RATED CURRENT | 20.83A | 10.42A | |
CURRENT RANGE | 0-20.83A | 0-10.42A | |
RATED POWER | 250 W | 250W | |
RIPPLE&NOISE(max) | 150mV | 150mV | |
CURRENT TOLERANCE | |||
SETUP RISE TIME | 80ms/120VAC,220VAC | ||
HOLD UP TIME(Typ.) | 60ms/120VAC,220VAC | ||
INPUT | VOLTAGE RANGE | 100~265VAC | |
FREQUENCY RANGE | 50~60Hz | ||
POWER FACTOR(Typ.) | >PF0.97@120VAC & 220VAC | ||
EFFICIENCY(Typ.) | ﹥89% | ||
AC CURRENT(Typ.) | 1.85A/120VAC,220VAC | ||
INRUSH CURRENT (Typ.) | COLD START 50A/120VAC,220VAC | ||
PROTECTION | Short circuit | Protection type:recovers automatically after condition is removed | |
Overload | overload protected@145-160% above peak rating | ||
Over temperature | Protection type:Shut down o/p voltage,re-power on to removed | ||
ENVIRONMENT | WORKING TEMP. | -40~+50℃ (Refer to output load derating curve) | |
WORKING HUMIDITY | 20~99% RH non-condensing(Waterproof) | ||
STORAGE TEMP.,HUMIDITY | -40~+80℃,10~99%RH | ||
SAFETY&EMC | SAFETY STANDARDS | ETL/cETL,CE Mark(EMC ,LVD),IP67 | |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC IP-GND:1.5KVAC | ||
EMC Test Standards | EN55015:2006;EN61547:1995+2000;EN61000-3-2:2006 | ||
EN61000-3-3:1995+A2:2005;EN61346-1:2001;EN61347-2-13:2006 | |||
NOTE | 1.All parameters NOT specially mentoned are measured at 120~220VAC input,rated load and 25℃ of ambient temperature. | ||
2.Ripple&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&10uf parallel capacitor. | |||
3.Tolerance:includes set up tolerance,line regulation and load regulation. |