5 in 1 Dimmable LED Driver 30W (Standard Size)
This phase cut dimmable driver 30W combines two types of dimming mode: triac and 0-10v, which is a strength in the LED market.
model | SMT-012-030VTD | SMT-024-030VTD | |
Output | DC Voltage | 12V | 24V |
Voltage Tolerance | ±0.5V | ±0.5V | |
Voltage Regulation | ±0.5% | ||
Rated current | 2.50A | 1.250A | |
Load Regulation | ±1% | ||
Rated power | 30W | 30W | |
Input | Voltage Range | 100-277V AC | |
THD(Typ. ) @ full load | <20%@120VAC &277VAC | ||
Frequency Range | 47~63HZ | ||
Power Factor ( Typ.) | 0.99@120VAC 0.98@277VAC | 0.99@120VAC 0.95@277VAC | |
Full Load Efficiency(Typ.) | 79%@120VAC 80%@277VAC | 79%@120VAC 80%@277VAC | |
AC Current(Typ.) | 0.5A | ||
Inrush Current (Typ.) | 7A, 50%, 420us @120VAC; 12A, 50% , 480us @277VAC | ||
Leakage current | <0.5mA | ||
Protection | Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | |
Short Circuit | shut down o/p voltage, re-power on to recover after fault condition removed | ||
Over Loading | ≤120% Hiccup mode,recovers automatically after fault condition is removed | ||
Environment | Working TEMP. | -40~+60℃ (see below derating curve) | |
Working Humidity | 20 - 95%RH,non-condensing | ||
Storage TEM.,Humidity | -40 - +80℃,10 - 95%RH | ||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | ||
Vibration | 10~500Hz, 2G 10min./1 cycle,period for 60min. each along X,Y,Z axes | ||
Safety&EMC | Safety standards | UL8750+UL1310 , CAN/CSA-C22.2 No.250.13 | |
Withstand voltage | I/P-O/P:1.88KVac | ||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||
EMC EMISSION | FCC 47 CFR Part 15 ,Subpart B | ||
Others | Weight | About 0.25Kg | |
Size | 155*54*20mm (L*W*H) | ||
packing | Carton size: 350*240*130mm , 40PCS/CTN (L*W*H) | ||
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input , rated load and 25℃of ambient temperature. | ||
2. Tolerance: includes set up tolerance, line regulation and load regulation . | |||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |
Dimming Operation and Connecting Diagram
¡ùUsing two ways of dimming at the same time, you must be assured that LED lighting is up to the max. Brightness then you could operate with the other dimming;
¡ùUsing one dimming ---TRIAC/Phase cut dimming
1.The Pulse-Width Modulation (PWM) of output voltage can be adjusted through input terminal of the AC phase line(L) by connection a phase /Triac dimmer of lighting system.
2.Working with forward phase /leading edge ,MLV and Reverse phase /trailing edge ,ELV,TRIAC dimmers
3.Min loading is about 10%
4.Please try to use dimmers with power at least 1.5 times as the output power of the driver.