Slim Size 0-10V Dimmable Driver 100W(IP67)
SMT-012-100VDSW
0-10V Dimmable Driver
SMARTS
Smarts SMT-012-100VDSW is a 24 volt 100w dimmable constant voltage led driver The shell is aluminum, suitable for outdoor. its 0-10v dimmable power supply could drive your 0-10v led lights Has a 7-...
Smarts SMT-012-100VDSW is a 24 volt 100w dimmable constant voltage led driver The shell is aluminum, suitable for outdoor. its 0-10v dimmable power supply could drive your 0-10v led lights Has a 7-year warranty
model | SMT-012-100VDSW | SMT-024-096VDSW | |
Output | DC Voltage | 12VDC | 24VDC |
Voltage Accuracy | ±5% | ±5% | |
Rated current | 8.33Amp | 4Amp | |
Rated power | 100W | 96W (class 2) | |
Voltage Regulation | ±0.5% | ||
Load Regulation | ±1% | ||
Input | Voltage Range | 100-277 VAC | |
Frequency Range | 47~63HZ | ||
Power Factor ( Typ.) | PF≧0.99/110V ; PF≧0.95/277V | ||
THD(Typ. ) @ full load | <10%@120VAC <15%@277VAC | ||
Full Load Efficiency(Typ.) | 84%@120VAC, 86%@277VAC | 85%@120VAC, 88%@277VAC | |
AC Current(Typ.) | 1.40A | ||
Inrush Current(Typ.) | 11A,50%,1.04ms@110V, 27A,50%,960us@277V | ||
Leakage current | <0.50mA | ||
Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. | |
Over Loading | ≤120% shut down o/p voltage, re-power on to recover | ||
Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||
Environment | Working TEMP. | -40~+60℃ | |
Working Humidity | 20~95%RH,non-condensing | ||
Storage TEM.,Humidity | -40~+80℃,10~95%RH | ||
TEMP.coefficient | ±0.03%/℃(0~50℃) | ||
Vibration | 10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes | ||
Safety&EMC | Safety standards | UL8750 ,CAN/CSA-C22.2 No.250.13 | |
Withstand voltage | I/P-O/P: 1.88KVAC | ||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||
EMC EMISSION | FCC 47 CFR Part 15 ,Subpart B | ||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,,11, ,Alight industry level | ||
Others | Weight | 0.55Kg | |
Size | 330*32*23mm (L*W*H) | ||
packing | 360*27*17.5mmmm , 50PCS/CTN | ||
Notes | 1. All parameters NOT specially mentioned are measured at 110VAC, 277VAC input , | ||
Rated load and 25℃of ambient temperature. | |||
2. Tolerance:includes set us tolerance,line regulation and load regulation . | |||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |
?