Bulk purchases

All products can enjoy free shipping service if the price is over $50. If you require drivers more than 30pcs, please feel free to contact us online, (or email: sales1@smartspower.com), we will provide the best purchasing plan

5 in 1 Dimmable LED Driver 60W (Junction Box)

SMT-12060-VTD-J
5 in 1 Dimmable LED Driver
SMARTS
Constant voltage triac and 0 10v dimmable LED driver 12v 60W integrated with junction box design. Input voltage range is 100-277vac. Working efficiency is up to 91%. Dimming range is 0~100%, smooth...
$67.00

Constant voltage triac and 0 10v dimmable LED driver 12v 60W integrated with junction box design. Input voltage range is 100-277vac. Working efficiency is up to 91%. Dimming range is 0~100%, smooth and flicker-free. Suitable for indoor LED lighting project installation. Warranty 7 years.

Model SMT-12060-VTD-J SMT-24060-VTD-J SMT-48060-VTD-J
Certificate UL / cUL / FCC / Class P / Class 2
Output DC Voltage 12V 24V 48V
Voltage Tolerance ±5% ±3% ±2%
Voltage Regulation ≤0.5% ≤0.5% ≤0.5%
Load Regulation ≤2% ≤1% ≤1%
Rated current 5A 2.5A 1.25A
Rated power 60W
Voltage Ripple 500mVp-p 450mVp-p 450mVp-p
Overshoot voltage <7%(full load) <5%(full load) <5%(full load)
Output volt Adjustment 12-13V    24-26V    48-50V   
Output mode selection The DIP switch in the "ON" position represents the PWM (Pulse - Width Modulation) mode, and in the "1" position represents the VR (Modulation of DC Voltage) mode.
Switching the output mode requires the power to be cut off for 3 seconds and then powered on again for the mode switching to take effect.
Input Voltage Range 100-277VAC
Frequency Range 47 - 63Hz
Power Factor (Typ.) @ full load >0.98@120VAC
>0.97@277VAC
>0.98@120VAC
>0.97@277VAC
>0.98@120VAC
>0.97@277VAC
THD(Typ. ) @ full load <15%@120V  <15%@277V
Efficiency(Typ.) @ full load ≥83%@120VAC
≥84%@277VAC
≥83%@120VAC
≥85%@277VAC
≥84%@120VAC
≥86%@277VAC
AC Current (Max.) ≤0.75A @120VAC  ≤0.3A@277VAC
Standby power ≤0.5W
Inrush Current (Typ.) 31.6A,152us@50%Ipeak 120VAC     76.8A,156us@50%Ipeak 277VAC
Leakage current <0.5mA
Protection Short Circuit Hiccup mode, can be automatically restored after abnormal removal
Over Load ≥120%,Constant - Current Mode, automatic recovery after exception
Over temperature When the ambient temperature exceeds 55℃ ±5℃, the output is turned off
Environment Working TEMP. -40~+40℃ (see below derating curve)
Working Humidity 20 - 95%RH  non-condensing
Storage TEM.,Humidity -40 - +80℃,10 - 95% RH non-condensing
TEMP.coefficient ±0.03%/℃(0 - 50℃)
Vibration 10 ~ 500Hz, 5G 12 minutes/cycle, X Y Z axis 72 minutes each
Safety & EMC Safety standards UL8750  CAN/CSA-C22.2 No.250.13
Withstand voltage I/P-O/P:1.88KVac;I/P-FG::1.88KVac;O/P-FG:0.5KVac
Isolation resistance I/P-O/P:100MΩ / 500VDC / 25℃ / 70% RH
Surge Immunity Test AC Power Line:Differential Mode 2KV,Common Mode 4KV
EMC Immunity FCC/ICES do not request this test
EMC Emission FCC Part15 Subpart B;ANSI C63.4:2017;ICES-005 Issue 5
Others Net Weight 0.9KG
Dimension 188*95.4*42.7mm(L*W*H)
Packing 415*265*270mm    20 pcs / CTN
Notes 1. All parameters NOT specially mentioned are measured at 120VAC input, rated load and 25℃of ambient temperature.
2. Tolerance: includes set up tolerance and load regulation .
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again.
4. Default states:The output mode is PWM output by default.   The dimming curve is a gamma2.2 curve.
5. Regarding LED driver load types where the driver meets the harmonic emissions requirements of ANSI C82.77-10.

Mechanical Specification

Dimming Operation

Using two ways of dimming at the same time, you must be assured that LED lighting is up to the max. Brightness then you could operate with the other dimming;

Using one dimming ---TRIAC/Phase cut dimming

1. The Pulse-Width Modulation (PWM) of output voltage can be adjusted through input terminal of the AC phase line(L) by connection

a phase /Triac dimmer or lighting system.

2. Working with Forward phase, MLV and Reverse phase, ELV, TRIAC dimmers or light system. 

3. Min. loading is about 10%

4. Please try to use dimmers with power at least 2 times as the output power of the driver.

Using one dimming ---0-10/ 1-10V/ 10V PWM/ Potentiometer dimming