model | SMT-024-080VWJ (1.0 version) SMT-024-080VWJV2 (2.0 version) |
||
Output | DC Voltage | 24V | |
Voltage Accuracy | ±0.5V | ||
Rated current | 3.33A | ||
Rated power | 80W | ||
Input | Voltage Range | 100-277VAC | |
Frequency Range | 47-63Hz | ||
Power Factor(Typ.)@ full load | 0.99@120VAC 0.97@230VAC 0.95@277VAC | 0.99@120V ; 0.96@230V ;0.97@277V | |
THD(Typ.)@ full load | <15%@120VAC <20%@230VAC <20%@277VAC | ||
Efficiency(Typ.)@ full load | 80% @120VAC 85%@230VAC 84%@277VAC | 83%@120V 87%@230V 86%@277V | |
AC Current(Max.) | 1.2A (100VAC) | ||
Inrush Current (Typ.0 | 20A,50% ,1.6ms@120V ; 30A,50% 200us@230V ; 25A,50% 1.2ms@277V | ||
Leakage current | <0.50mA | ||
Protection | Short Circuit | shut down o/p voltage, re-power on to recover after fault condition removed | |
Over Loading | ≤120% constant current limiting, auto-recovery | ||
Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | ||
Environment | Working TEMP. | -40~+60℃ (see below derating curve) | |
Working Humidity | 20~90%RH, non-condensing | ||
Storage TEMP. Humidity | -40~+80℃,10~95%RH | ||
TEMP .coefficient | ±0.03%/℃(0~50℃) | ||
Vibration | 10~500Hz, 5G 10min./1 cycle, period for 60min. each along X,Y,Z axes | ||
Safety&EMC | Safety standards | UL8750+UL1310 | |
Withstand voltage | I/P-O/P:1.88KVAC | ||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | ||
EMC EMISSION | FCC Part 15 B | ||
Others | Weight | 1.3Kg | |
Size | 1.0 version: 220*93*40mm (L*W*H) / 2.0 version: 220*94.5*40mm | ||
packing | 10PCS/CTN 385*335*200mm 20PCS/CTN | ||
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input , rated load and 25℃of ambient temperature. | ||
2. Tolerance:includes set us tolerance,line regulation and load regulation . |